Power range: 25÷2500 kVA.
ТМГ – Three-phase oil transformer.
| Technical Specifications of ТМГ Transformers with 25÷2500 kVA Rated Power and Standard Losses | |||||||
|
Rated power, kVA
|
Type |
Rated voltage, kV
|
Winding connection scheme and vector group
|
Losses
|
Short-circuit voltage, %
|
No-load current, % | |
|
No-load, W
|
Short-circuit, W
|
||||||
| 25 | ТМГ-25 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
120 |
600 |
4 | 2,0 |
| 40 | ТМГ-40 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
160 | 900 | 4 | 1,8 |
| 63 | ТМГ-63 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
220 | 1280 | 4 | 1,6 |
| 100 | ТМГ-100 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
280 | 1970 | 4 | 1,4 |
| 160 | ТМГ-160 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
450 | 2700 | 4 | 1,2 |
| 250 | ТМГ-250 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
610 | 3800 | 4 | 1,0 |
| 400 | ТМГ-400 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 |
780 | 5600 | 4 | 0,8 |
| 630 | ТМГ-630 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 1070 | 8300 | 5 | 0,6 |
| 1000 | ТМГ-1000 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 1470 | 12200 | 5 | 0,4 |
| 1250 | ТМГ-1250 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 1740 | 15000 | 6 | 0,3 |
| 1600 | ТМГ-1600 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 1700 | 18000 | 6 | 0,25 |
| 2500 | ТМГ-2500 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 2500 | 28000 | 7 | 0,2 |
|
Technical Specifications of TMG Transformers with 25÷2500 kVA Rated Power and Reduced Losses
|
||||||
|
Rated power, kVA
|
Rated voltage, kV
|
Winding connection scheme and vector group
|
Losses
|
Short-circuit voltage, %
|
No-load current, %
|
|
|
No-load, W
|
Short-circuit, W
|
|||||
|
25
|
6 (10)/0,4
|
У/Ун-0; Д/Ун-11; У/Zн-11
|
100 | 540 | 4 | 3,5 |
|
40
|
6 (10)/0,4
|
У/Ун-0; Д/Ун-11; У/Zн-11
|
125
|
850 | 4 | 3,0 |
|
63
|
6 (10)/0,4
|
У/Ун-0; Д/Ун-11; У/Zн-11
|
200
|
1160 | 4 | 2,5 |
| 100 |
6 (10)/0,4
|
У/Ун-0; Д/Ун-11; У/Zн-11
|
250
|
1750 | 4 | 2,0 |
|
160
|
6 (10)/0,4
|
У/Ун-0; Д/Ун-11; У/Zн-11
|
375
|
2350 | 4 | 1,5 |
|
250
|
6 (10)/0,4
|
У/Ун-0; Д/Ун-11; У/Zн-11
|
425
|
2955 | 4 | 1,25 |
|
400
|
6 (10)/0,4
|
У/Ун-0; Д/Ун-11
|
565
|
4181 | 4 | 1,0 |
| 630 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 695 | 6136 | 5 | 0,75 |
| 1000 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 956 | 9545 | 5 | 0,6 |
| 1250 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 1350 | 13250 | 5 | 0,5 |
| 1600 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 1700 | 15000 | 6 | 0,4 |
| 2500 | 6 (10)/0,4 | У/Ун-0; Д/Ун-11 | 2400 | 24000 | 6 | 0,4 |
Transformers with rated power from 25 kVA to 250 kVA are manufactured with winding connection scheme and vector group
У/Zн-11
.
|
Transformer Overall Dimensions
|
||||||||
|
Rated power, kVA |
Length (L), mm |
Width (B), mm |
Height (H), mm |
Distance between High Voltage (HV) insulators (K), mm |
Distance between center lines of the channel bars |
Oil mass, kg |
Total mass, kg |
|
|
Along longitudinal axis (A), mm | Along transverse axis (A1), mm | |||||||
|
25 |
840 |
550 |
850 |
170 |
450 |
400 |
80 |
295 |
|
40 |
840 |
550 |
900 |
170 |
450 |
400 |
95 |
345 |
|
63 |
970 |
570 |
1235 |
170 |
500 |
400 |
120 |
500 |
|
100 |
1000 |
730 |
1355 |
190 |
550 |
450 |
150 |
665 |
|
160 |
1080 |
760 |
1450 |
190 |
550 |
550 |
185 |
900 |
|
250 |
1225 |
790 |
1560 |
230 |
550 |
550 |
290 |
1225 |
|
400 |
1360 |
810 |
1720 |
230 |
660 |
660 |
360 |
1660 |
|
630 |
1560 |
1040 |
1800 |
230 |
660 |
660 |
515 |
2370 |
| 1000 | 1845 | 1150 | 1950 | 230 | 820 | 820 | 655 | 3150 |
| 1600 | 1985 | 1295 | 2350 | 250 | 1070 | 1070 | 1100 | 4680 |
| 2500 | 2190 | 1680 | 2710 | 250 | 1070 | 1070 | 1245 | 6900 |
By clicking the “Calculate” button, you consent to the processing of personal data.
Your name
Phone