Energy-efficient, low-loss two-winding power transformers with OLTC, type TDNS-10000÷16000/35-U1 (UHL1).

product
Power transformer, three-phase, double-winding, with natural oil circulation and forced air cooling, equipped with an on-load tap changer (OLTC). Automatic control is performed by an automatic controller supplied together with the transformer. It is intended for operation in auxiliary power systems of power plants. The use of a TDNS-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Get the cost
Application sent

By clicking the “Calculate” button, you consent to the processing of personal data.

Description

Power transformer, three-phase, double-winding, with natural oil circulation and forced air cooling, equipped with an on-load tap changer (OLTC). Automatic control is performed by an automatic controller supplied together with the transformer. It is intended for operation in auxiliary power systems of power plants. The use of a TDNS-type transformer ensures reliable power supply to the consumer throughout the entire service life.

Power range

Power range: 10,000÷16,000 kVA.
Primary winding voltage HV: 36.75; 35 kV.
Climatic version: U1 or UHL1.


Transformer symbols

T – Transformer
D – With natural oil circulation and forced air circulation.
N – Equipped with on-load tap changing (OLTC).
S – Intended for operation in the auxiliary power systems of power plants.
H – Rated power, kVA.
35 – Voltage class, kV.
U1 or UHL1 – Climatic version and placement category according to ГОСТ 15150.


Characteristic

Каталог.cdr


Technical specifications of TDNS-10000÷16000/35-U1(UHL1) energy-efficient transformers with reduced losses

Transformer type

Rated power, kVA

Rated voltage, kV Winding connection diagram and vector group

Losses, kW

Short-circuit voltage, %

No-load current, %

HV LV

No-load

Short-circuit 

TDNS-10000/35 

10000 36,75 10,5; 6,3 Yn/D-11

11,5

60,0

8,0

0,75

TDNS-16000/35 

16000 36,75 10,5; 6,3 Yn/D-11

17,0

85,0

10

0,70

Overall and Mounting Dimensions

Overall dimensions of transformers type TDNS-10000÷16000/35-U1(UHL1)
Transformer
type
Overall dimensions, mm        Weight, kg

B
H
H1
H2
H3
A N K Total Transport Oil
TDNS-10000/35  
4125
3265
3685
1935
550
995
1524
1000
300 19430 16260 4100
TDNS-16000/35 
4470
3415
3922
135
585
850
1524
1000
400 26000 22145 5250

Dimensional drawings

print
Power transformer, three-phase, double-winding, with natural oil circulation and forced air cooling, equipped with an on-load tap changer (OLTC). Automatic control is performed by an automatic controller supplied together with the transformer. It is intended for operation in auxiliary power systems of power plants. The use of a TDNS-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Get the cost
Please fill in all fields with *
Application sent

By clicking the “Calculate” button, you consent to the processing of personal data.

team
Tusov Artem Aleksandrovich
Deputy Director for Marketing and Sales

Can't decide?

Consultation and equipment selection over the phone

Your name

Phone

Your application has been submitted for development
[10]
By clicking the “Request a call” button, you consent to the processing of personal data.