О – Bir fazali
ДЦ – Majburiy havo va moy aylanishi
Э – Elektr podvijnoy tarkibda ishlash uchun
2000 – Nominal quvvat, kVA
25 – Tarmoq o‘rashining nominal kuchlanishi, kV
У1 – Joylashtirish toifasi va iqlim ijrosi ГОСТ 15150 bo‘yicha
|
ОДЦЭ-2000/25П-У1; ОДЦЭР-1600/25П-У1
turidagi transformatorlar
|
||
|
Parametr nomi
|
Qiymat | |
|
Transformator turi
|
ОДЦЭ-2000/25П-У1
|
ОДЦЭР-1600/25 П-У1
|
|
Tarmoq o‘ramining nominal quvvati, kVA
|
1600
|
965
|
|
Tarmoq o‘ramining nominal kuchlanishi, kV
|
25
|
25
|
|
Nominal chastota, Hz
|
50
|
50
|
|
Tortish o‘ramining nominal quvvati, kVA
|
1320
|
773
|
| Tortish o‘rami chiqishlaridagi nominal kuchlanish, V |
1-42200
|
1-8 2208 |
|
(1-2)-(1-0)-(1-3)-(1-4)550-1100-1650-2200
|
||
| O‘z ehtiyojlar o‘ramining nominal quvvati, kVA | 2х50=100 | 92 |
|
O‘z ehtiyojlar o‘rami chiqishlaridagi nominal kuchlanish, V
|
а₂-а₃; а₄-а₅ 220
|
х₁-0₁ 220 |
| а₂-х₂; а₄ -х₄ 280 | х₂-0₁ 276 | |
| Isitish o‘ramining nominal quvvati, kVA | 140 | 100 |
| Isitish o‘ramining nominal kuchlanishi, V | 630 | 628 |
| Qo‘zg‘atish o‘ramining nominal quvvati, kVA | 2х16=32 | - |
|
Qo‘zg‘atish o‘rami chiqishlaridagi nominal kuchlanish, V: a₆–x₆; a₇–x₇ |
120 | - |
| Chulg‘amlar ulanish sxemasi va vektor guruhi | 1/1-1-1-1-1-1-0-6-6-6-6-6 | 1/1-1-1-0-0-6 |
| Transformatorning umumiy yo‘qotishlari, kW | 36,5 | 22 |
| Moy massasi, kg | 900 | 940 |
| Jami og‘irlik, kg |
3560
|
3680 |
“Hisoblash” tugmasini bosish orqali siz shaxsiy ma'lumotlarni qayta ishlashga rozilik bildirasiz.
Ismingiz
Telefon raqam