Quality in every winding. Reliability in every delivery.
About the Plant
Learn more about the equipment used, the technology, the product development, creation and testing process, and the company's long history. Here you can see certificates indicating access to all types of work performed.
Check out our catalog of quality, modern and energy efficient products. We also offer individual development of transformers to suit the needs and wishes of customers.
Here you can familiarize yourself with all the necessary documentation, see our financial reports and development plans. And also ensure the competence of the governing board.
News in which news is published about all the changes that have occurred in the work of the enterprise. Also here you can read announcements about planned changes or ongoing events for investors and partners.
Have any questions about products or want to become a partner? Use the contacts of our factory or representative office in the Russian Federation to contact our specialists.
We create transformers for the stable energy supply of humanity
Our products operate reliably in power generation, including from renewable sources that are not depleted during operation and do not cause serious harm to the environment, in power distribution systems, at enterprises in the oil, gas, coal, mining, and metallurgical industries, in agriculture, and in railway transport.
Be the first to learn about current projects, events, and new records at the ChTZ plant
E-mail
You are subscribed
Please fill in all fields with *
By clicking the “Subscribe” button, you consent to the processing of personal data.
02Our products
Three-winding power transformers with РПН, Type ТДТН-25000÷63000/220-У1(УХЛ1)
Three-phase, three-winding power transformer with natural oil circulation and forced air circulation, featuring on-load voltage regulation (РПН) and off-load tap changer (ПБВ). Automatic control is provided via an automatic controller supplied with the transformer. Using ТДТН-type transformers ensures reliable power supply throughout the entire service life.
Transformer type ТРДЦН-63000/220-У1 — energy-efficient, with reduced losses.
The transformer ТРДЦН-63000/220-У1 is a power, two-winding unit equipped with split Low Voltage LV windings, a bell-type tank, forced air and oil circulation, and on-load tap changing (РПН).
The transformer is manufactured for moderate climate conditions and is designed for operation at ambient temperatures from –45°C to +40°C.
It features a flat-laminated magnetic core made of high-quality electrical steel.
The windings are made of copper conductor.
The transformer complies with the requirements of ГОСТ 17544.
Three-winding power transformers with РПН, type ТДТН-16000÷63000/150-У1(УХЛ1)
Three-phase, three-winding power transformer with natural circulation of oil and forced air circulation, with voltage regulation under load (РПН) and off-load tap changer (ПБВ). Automatic control is performed via an automatic controller supplied together with the transformer. Using a ТДТН-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Two-winding power transformers with РПН, type ТДН-10000÷40000/110-У1(УХЛ1)
The power transformer is a three-phase, double-winding type with natural oil circulation and forced air circulation, equipped with an on-load tap changer (РПН). Automatic control is carried out by an automatic controller supplied together with the transformer. The use of a ТДН-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Energy-efficient two-winding power transformers with split НН windings and on-load tap-changer (RПН), type ТРДНС-25000/35-У1(УХЛ1), featuring reduced losses
The power transformer is a three-phase, double-winding, oil-filled type with natural oil circulation and forced air circulation, equipped with an on-load tap changer (РПН). Automatic control is carried out by an automatic controller supplied together with the transformer. It is intended for use in the auxiliary power systems of power plants. The use of a ТРДНС-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Three-winding power transformers with РПН, type ТМТН-6300/110-У1(УХЛ1)
Three-phase, three-winding power transformer with natural circulation of oil and air, with voltage regulation under load (РПН) from the High Voltage HV side. Automatic control is performed via an automatic controller supplied together with the transformer. Using a ТМТН-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Two-winding power transformers with РПН, type ТМН-2500-6300/110-У1(УХЛ1), energy-efficient, with reduced losses
Power transformers, three-phase, double-winding, with natural oil circulation, equipped with on-load tap changers (РПН). Automatic control is carried out by an automatic controller supplied together with the transformer. The use of ТМН-type transformers ensures reliable power supply to the consumer throughout the entire service life.
Energy-efficient, low-loss two-winding power transformers with OLTC, type ТДНС-10000÷16000/35-У1 (УХЛ1).
Power transformer, three-phase, double-winding, with natural oil circulation and forced air cooling, equipped with an on-load tap changer (РПН). Automatic control is performed by an automatic controller supplied together with the transformer. It is intended for operation in auxiliary power systems of power plants. The use of a ТДНС-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Power Transformers, Two-Winding, with ПБВ, Type ТД-10000÷16000/35-У1(УХЛ1), Energy-Efficient, Reduced Losses
These power transformers are three-phase, two-winding units featuring natural oil circulation and forced air circulation, equipped with no-load voltage regulation (ПБВ). The voltage regulation range on the ВН side is ±2×2.5%. The transformer is designed for operation in electrical networks. The use of ТД-type transformers ensures reliable power supply to consumers throughout their entire service life.
Two-winding power transformers with ПБВ, type ТМ-1000÷6300/35-У1(УХЛ1)
Power transformers, three-phase, double-winding, with natural oil and air circulation, equipped with off-circuit tap changers (ПБВ). They are intended for use in power transmission systems, providing minimal electrical losses in transmission lines. The use of TM-type transformers ensures reliable power supply to the consumer throughout the entire service life.
Explosion-proof complete transformer substation, type КТПВ
Explosion-proof complete transformer substations КТПВ, with rated power from 100 to 630 kVA, are designed to supply three-phase AC power to electrical equipment installed in underground workings hazardous due to gas and dust, as well as to provide leakage-current protection and maximum current protection of low-voltage lines. The substation is equipped with transformers of the ТСВ type.
The power transformer is assembled on a core-type magnetic circuit made of cold-rolled electrical steel with low specific losses.
The magnetic core of the power transformer is three-phase, core-type, manufactured using “Step-Lap” technology from cold-rolled grain-oriented electrical steel. The lamination stacking is performed in five sheets. The transformer windings are made of copper wire with heat-resistant insulation. Insulation type — aramid paper “prepreg” or “Nomex”. Winding type — multilayer cylindrical.
The ВН winding has tappings that allow adjusting the transformation ratio within ±5%, brought out to an insulation panel.
Components and operating principle of the substation:
The substation consists of a power transformer compartment, high-voltage switchgear (РУВН), low-voltage switchgear (РУНН), and a wheel assembly (optional).
By switching on the РУВН disconnector, the primary voltage is fed to the power transformer compartment. The power transformer converts the voltage of electric energy and transfers it to the РУНН. In the РУНН, the voltage is distributed and supplied to consumers.
The single-phase traction transformer is designed to convert the voltage of the contact network into the voltage required for the traction motor circuits and auxiliary systems of AC electric trains operating at 25 kV for suburban and local services.
Oil circulation is provided by an electric pump. The electric pump is mounted on the transformer and supplied as a complete assembly with the transformer.
Climatic version — У, placement category — 1, according to ГОСТ 15150 and ГОСТ 15543.1.
Three-phase oil distribution transformers, type ТМГ
Power transformers, three-phase, double-wound hermetically sealed, with natural oil cooling. The transformers are designed for converting electrical energy in the networks of the electricity consumers' power systems. The transformer windings are made in aluminum and copper versions, both from winding wires and foil. The transformer windings are round and oval in shape.
Single-phase oil-filled voltage transformers of the ЗНОМ type with natural cooling are scaling converters designed to generate measurement signals for electric measuring instruments, protection, and signaling circuits in AC networks with isolated neutral at frequencies of 50 and 60 Hz. They can be used indoors and outdoors in temperate climate zones under the following conditions: altitude not exceeding 1000 m above sea level, continuous operation mode, ambient temperature from -45°C to +40°C.
Power transformers, two-winding, movable on skids, type ТМНП-2500÷6300-У1(УХЛ1)
Three-phase, two-winding power transformers with natural oil circulation and on-load tap changer (РПН). Automatic control is performed via an automatic controller supplied with the transformer. Designed for operation in power transmission systems, ensuring minimal electrical losses in transmission lines. Transformers are movable on skids. Use of the ТМНП type transformer ensures reliable power supply to the consumer throughout the service life.
Two-winding power transformers with split winding НН, equipped with РПН, type ТРДН-25000÷63000/110-У1(УХЛ1)
The power transformer is a three-phase, double-winding type with a split low-voltage winding, natural oil circulation, and forced air circulation, equipped with an on-load tap changer (РПН). Automatic control is carried out by an automatic controller supplied together with the transformer. The use of a ТРДН-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Transformers type ТДТНЖ-16000÷40000 /110/27.5/11 for AC electrified railways
The ТДТНЖ transformer is a power, three-phase, three-winding, bell-type transformer with natural oil and air circulation, designed for railway applications. It is manufactured with rated powers of 16000, 25000, and 40000 kVA.
Transformers rated from 25000 kVA are produced with bell-type tanks.
These transformers are intended for supplying AC electrified railway networks.
The main technical parameters and manufacturing requirements comply with ГОСТ R 51559.
Three-phase oil-immersed distribution transformers, type ТМ
Power transformers, three-phase, double-winding, with an oil conservator and natural oil cooling. The conservator, mounted on the tank lid, has a ventilation opening connected through an air dryer. The oil pressure inside the transformer remains constant and does not depend on temperature.
Single-phase, oil-filled ОМ and converter ОМП transformers with natural oil cooling, connected to 50 Hz AC networks, are designed for converting electrical energy in power systems, supplying electrical equipment of railways, and other single-phase electricity consumers.
The transformer complies with Ts 00212908-03:2016; О´zDst requirements.
Transformers type ТДТНЖ-16000÷40000 /220/27,5/11 for electrified railways, AC
The ТДТНЖ transformer is a power, three-phase, three-winding, bell-type transformer with natural oil and air circulation, designed for railways, with ratings of 16000, 25000, 40000 kVA. Transformers with ratings from 25000 kVA are manufactured with bell-type tanks. These transformers are intended for supplying AC electrified railways.
Main technical parameters and manufacturing of transformers are according to ГОСТ Р 51559.
The traction transformer ОНДЦЭ-4350/25К-У2 is designed for freight electric locomotives ЭС5К, 2ЭС5К, 3ЭС5К, 4ЭС5К operating on 25 kV, 50 Hz AC electrified railways.
The transformer converts the contact line voltage to supply voltage for traction motors, excitation windings of traction motors, and auxiliary circuits of the locomotive. Additionally, the transformer enables inversion mode (converting traction motor voltage back to contact line voltage, excitation circuits, and auxiliary needs).
ОСМ series transformers with power ratings from 0.063 to 4.0 kVA, primary winding voltage from 220 to 660 V, and secondary winding voltage from 12 to 380 V are intended for supplying control circuits, local lighting, signaling, and automation systems.
The transformers comply with the requirements of ГОСТ 19294.
ТС3 series transformers are three-phase, dry-type, double-winding units designed for electrical energy conversion. Operating mode – continuous.
Ambient temperature range: –45°C to +40°C
Rated frequency: 50 Hz
Winding connection scheme and vector group: У/Ун-0 or Д/Ун-11
Protection degree: IP00 (IP21, IP31) according to ГОСТ 14234
ТСЛ and ТС3Л series three-phase, dry-type, double-winding transformers with cast insulation are designed for converting electrical energy. Operating mode — continuous. Ambient temperature from -45 °C to +40 °C. Relative humidity not more than 80% at +25 °C. Rated frequency — 50 Hz. Winding connection diagram and group: У/Ун-0 or У/Ун-11. Degree of protection: IP21 according to ГОСТ 14234.
The transformer is designed for use on mainline passenger electric locomotives to convert the contact network voltage into the voltage for traction motor circuits, excitation of auxiliary needs such as heating and train power supply, and also to convert the traction motor voltage back to the contact network, including excitation and train power supply. Oil circulation is provided by an electric pump. The electric pump is mounted on the transformer and supplied together with it.
Climatic design: У, installation category 2 according to ГОСТ 15150 and ГОСТ 15543.1
Three-phase oil-immersed railway transformers type ТМЖ
Three-phase oil-immersed transformers of the ТМЖ type with a power rating of 25–1600 kVA, with natural oil cooling and off-load tap changing, are connected to an AC network with a frequency of 50 Hz and are intended for converting three-phase AC electric power at a voltage of 27.5 kV into AC power at 0.4 kV to supply railway electrical equipment. The transformer is designed for operation in moderate climate regions at an altitude not exceeding 1000 meters above sea level. The transformer is manufactured in accordance with O’zDSt and Ts 00212908-08:2018 standards.
A transformer designed to convert the voltage of the contact network into the voltage for the traction motors and auxiliary circuits of the traction unit.
The transformer is designed to convert the voltage of traction motor circuits and the auxiliary circuits of units. Circulation is provided by an electric pump type 1ТТ 63/10-У2 (ТУ 3631-005-00220150-2006), and cooling sections are air-cooled. The electric pump is mounted on the transformer and supplied together with it.
The transformer meets the requirements of Ts 00212908-14:2018.
Three-winding power transformers with РПН, type TДТН-10000÷63000/110-U1 (УХЛ1)
Three-phase, three-winding power transformer with natural oil circulation and forced air cooling, with on-load voltage regulation (РПН), HV side regulation range ±9×1.78%, and tap-changing without excitation (ПБВ). Automatic control is performed by an automatic controller supplied together with the transformer. The use of TДТН-type transformer ensures reliable power supply to the consumer throughout the entire service life.
Power transformers with two windings and a split НН winding, with РПН, type ТРДН-32000/150-У1 (УХЛ1)
Three-phase, double-winding power transformer with a split LV winding, natural oil circulation and forced air cooling, equipped with on-load tap changer (РПН). Automatic control is performed by an automatic controller supplied together with the transformer. The use of a ТРДН-type transformer ensures reliable power supply to the customer throughout the entire service life.
Oil-filled current transformers are designed to convert and transmit measurement signals to metering devices, protection, automation, signaling, and control instruments in alternating current circuits of industrial frequency. They are used in 110 and 220 kV power networks.
Voltage transformers are designed to transmit measurement signals to measuring instruments and/or protection and control devices in alternating current installations of industrial frequency. They are used in 110 and 220 kV electrical networks.
Two-winding power transformers with РПН, type ТМН-1000÷10000/35-У1 (УХЛ1)
Three-phase, two-winding power transformers with natural oil circulation and on-load voltage regulation (РПН). Automatic control is performed by an automatic controller supplied together with the transformer. They are designed for use in long-distance power transmission systems, ensuring minimal electrical losses in transmission lines. The use of transformers of the ТМН type provides reliable power supply to the consumer throughout the entire service life.
Installation of transformer: ТМН-6300/35
Russia Kuzbass city 2024
03Our projects
Substation 35/6 kV "Yuliya"
Installation of transformer: ТМН-2500/35
Russia Krasnodar city 2024
03Our projects
Substation "Sputnik"
Installation of transformer: ТДТН-40000/110
Uzbekistan Tashkent city 2024
03Our projects
Substation "Promyshlennaya"
Installation of transformer: ТДН-25000/110
Russia Kurgan city 2024
03Our projects
Substation "Urgench"
Installation of transformer: ТДТНЖ-40000/110
Uzbekistan Khorezm city 2024
03Our projects
Substation "Parvoz"
Installation of transformer: ТДТНЖ-40000/220 Uzbekistan Bukhara city 2025
03Our projects
Substation "Olmos"
Installation of transformer: ТДТН-63000/110
Uzbekistan Tashkent city 2025
03Our projects
Substation 356 kV "Vostochnaya"
Installation of transformer: ТМН-4000/35
Russia Kogalym city 2024
03Our projects
Substation "Kizkaldok"
Installation of transformer: ТДТН-40000/110
Uzbekistan Tashkent city 2024
01 / 05
Next
Traction transformer for electric locomotives
04Radiators
Radiators that provide heat dissipation for 30-35% higher than plate-type models
ChTZ manufactures high-quality radiators using Italian Convett technology. The radiators are made from oval-section tubes, providing more efficient heat dissipation. This ensures reliable and safe operation of your equipment while reducing the overall dimensions of a transformer.
Chirchiq Transformer Plant – a transformer manufacturer in Uzbekistan!
JSC «Chirchiq Transformer Plant» is an enterprise established in the first half of the 1940s.
For more than 80 years, we have been designing and manufacturing transformer equipment.
By developing equipment for new substations and generation capacities, and by
improving the reliability of the power system, we strengthen Uzbekistan's
energy security and independence.
In recent years, the company's products have been supplied to more than 30
countries, including Russia, Kazakhstan, Kyrgyzstan, Tajikistan, Turkmenistan,
Georgia, Ukraine, India, Pakistan, Afghanistan, Moldova, Mongolia, Egypt,
Turkey, Vietnam, Korea, Morocco, Greece, Bulgaria, Poland, Iraq, Cuba and several
other nations.
06They trust us
The synthesis of time-tested manufacturing traditions, innovative solutions, and modern technologies is the key to long and fruitful cooperation!
We manufacture transformers tailored to the needs of operating organizations, industry specifics, and climatic and technical operating conditions. Chirchik Transformer Plant has established itself as an open and cooperative company that ensures design, production, and service support, taking into account all partner requirements. If you need a transformer, fill out the request form
(questionnaire)
and our specialists will contact you!
01 / 01
01 / 01
Kayumov Jamshid Ganievich
CEO
Can't decide?
Consultation and equipment selection over the phone
Your name
Phone
Please fill in all fields with *
Your application has been submitted for development